Note how the number 10 bare copper ground wire is shaped in the rear of the generator inlet box and then wrapped around the green ground screw using the included clamp.

The 10/3 Romex which will be entering the rear of the generator inlet box. The cable is protruding through the house siding.

The hole in the wood siding was made using two spade drill bits. First a 7/8" bit was used to drill an 1/8" deep hole to allow for the button connector. A 1/2" drill bit was used to drill all the way through into the basement.
These are the holes that were made using the included drill bit. It is also required to scrape and file the perimeter of the holes so that the screws can make good contact for grounding of the interlock kit.