Home Main Breaker Generator Interlock Kit 10/3 Stapled Along Rim Joist

10/3 Stapled Along Rim Joist

The number 10 bare copper ground wire is shaped in the rear of the generator inlet box and then wrapped around the green ground screw using the included clamp

The 10/3 Romex is stapled along the rim joist

A two screw metal Romex connector was used to secure the10/3 Romex to the top of the circuit breaker panel
The 10/3 Romex is secured to the rim joist using BX staples.